Electrical Installation Complex; Equipment and Specifications: The laboratory equipment set for installation and study includes three VA88-32 3P automatic switches; three EP-32/33 electric drives; three PM32/33 undervoltage releases; three DK32/33 auxiliary contacts; three AK32/33 emergency contacts; three REK 77/4 intermediate relays; two voltage control relays; two PCT-80-1 static current relays; eight 1-pole automatic switches; one contactor; one rotary switch; two light phase indicators; six lighting fittings; six lighting fixtures with voltage indication; four power (voltage) regulators; electrical installation products and accessories; and wiring for circuit assembly.
Technical Characteristics: The system operates on a ~220 V, 50 Hz power supply and has a power rating of 2.0 kW. The overall dimensions are 1310 mm (width), 850 mm (height), and 590 mm (depth), with a total weight of 50 kg.